diff --git a/docs/requirements.md b/docs/requirements.md index 9508a8c..8a8377d 100644 --- a/docs/requirements.md +++ b/docs/requirements.md @@ -127,8 +127,8 @@ Any ship, module, building, or assembler recipe id that appears in no unlock gro - REQ-BLD-GHOST: While in builder mode, a ghost of the building is rendered at the tile under the cursor, showing where it would be placed. The ghost is drawn semi-transparently in the building type's own visuals — its `fill` and `outline` colors and `glyph` from `visuals.toml` — so that different building types are visually distinguishable in builder mode rather than all looking alike. When the current cursor position is invalid, the ghost instead uses the distinct "invalid" color (REQ-BLD-PLACE-VALID), which overrides the per-building coloring. - REQ-BLD-ROTATE: While in builder mode, pressing Shift+R rotates the ghost 90° clockwise and R rotates it 90° counter-clockwise. Rotation affects the direction of the output port. - REQ-BLD-PLACE: Clicking a valid tile in builder mode places a construction site and adds it to the build queue, consuming building blocks from the global stock. (For belts, placement is instead deferred to a drag gesture and happens on mouse release — REQ-BLD-BELT-DRAG.) -- REQ-BLD-PLACE-VALID: A placement position is valid only if (a) every footprint cell in the rotated `surface_mask` is satisfied by the underlying terrain — `A` cells coincide with asteroid tiles, `S` cells coincide with space tiles — (b) no footprint cell overlaps an existing placed building or construction site, except as allowed by REQ-BLD-ROTATE-IN-PLACE, and (c) the player has enough building blocks to afford the building. The ghost (REQ-BLD-GHOST) is rendered in a distinct "invalid" color — overriding its per-building coloring (REQ-BLD-GHOST) — when the current cursor position fails any of these conditions. -- REQ-BLD-ROTATE-IN-PLACE: If the ghost's footprint exactly coincides with the footprint of an existing placed building or construction site of the same building type, clicking places no new construction site and consumes no building blocks. Instead, the existing building or site is rotated to match the ghost's rotation. If the target is a construction site, its construction progress is preserved. **Exception:** Tunnel Entries and Tunnel Exits are never rotated in place — re-orienting a tunnel requires deconstructing and re-placing it (REQ-BLD-TUNNEL-MODE). A tunnel ghost whose footprint coincides with an existing tunnel is therefore treated as an ordinary occupied-tile placement (invalid in normal builder mode; skipped in blueprint placement mode). This applies in both normal builder mode and blueprint placement mode; in blueprint placement mode it is evaluated per building in the blueprint independently — buildings in the blueprint whose footprint coincides with an existing same-type building or site are rotated in place, while the remaining buildings in the blueprint are placed as normal construction sites (subject to the usual validity checks and total cost). +- REQ-BLD-PLACE-VALID: A placement position is valid only if (a) every footprint cell in the rotated `surface_mask` is satisfied by the underlying terrain — `A` cells coincide with asteroid tiles, `S` cells coincide with space tiles — (b) no footprint cell overlaps an existing placed building or construction site, except as allowed by REQ-BLD-ROTATE-IN-PLACE (builder mode) or REQ-UI-BLUEPRINT-OVERLAP and REQ-UI-BLUEPRINT-TRANSFER (blueprint placement mode), and (c) the player has enough building blocks to afford the building. The ghost (REQ-BLD-GHOST) is rendered in a distinct "invalid" color — overriding its per-building coloring (REQ-BLD-GHOST) — when the current cursor position fails any of these conditions. +- REQ-BLD-ROTATE-IN-PLACE: If the ghost's footprint exactly coincides with the footprint of an existing placed building or construction site of the same building type, clicking places no new construction site and consumes no building blocks. Instead, the existing building or site is rotated to match the ghost's rotation. If the target is a construction site, its construction progress is preserved. **Exception:** Tunnel Entries and Tunnel Exits are never rotated in place — re-orienting a tunnel requires deconstructing and re-placing it (REQ-BLD-TUNNEL-MODE). A tunnel ghost whose footprint coincides with an existing tunnel is therefore treated as an ordinary occupied-tile placement, which is invalid. This applies **only in normal builder mode**, including the belt drag of REQ-BLD-BELT-DRAG. Blueprint placement mode never rotates an existing building in place: there, a ghost whose footprint coincides with an existing same-type building or site is a configuration-transfer target (REQ-UI-BLUEPRINT-TRANSFER), or a compatible overlap that is left untouched (REQ-UI-BLUEPRINT-OVERLAP), or else an ordinary occupied-tile overlap, which is invalid. - REQ-BLD-BELT-DRAG: **Belt drag placement.** For belts, placement is a deferred drag gesture rather than immediate per-tile placement: construction sites are not placed while the cursor hovers new tiles, but only once the player releases the left mouse button. Pressing the left mouse button in the game world while in belt builder mode starts a drag anchored at the tile under the cursor. As the cursor moves, a **rectilinear (L-shaped) path** of belt tiles is computed from the anchor tile to the tile under the cursor: the path first runs along the axis **parallel to the belt's current orientation** (REQ-BLD-ROTATE) — stepping toward the cursor's coordinate on that axis to a corner tile — and then runs along the orthogonal axis to the cursor tile. When the cursor shares the anchor's row or column the path degenerates to a straight line, and when it is on the anchor tile the path is a single tile. - **Snapping to a building.** When the tile under the cursor is occupied by a non-belt building or construction site (the **target**), the path does not end on that occupied tile. Instead the end tile is the tile **closest to the cursor** (by distance from the cursor position to the tile) among the tiles orthogonally adjacent to the target across one of its **input-capable edges** — any footprint edge that is not one of the target's output ports, i.e. an edge on which the target can accept an incoming item (REQ-MAT-INPUT-PORTS for buildings, REQ-MAT-ACCEPT-DIR for splitters and tunnels). The geometrically closest such tile is **always** used, even if it turns out not to be a valid belt endpoint — in that case it is previewed and applied by the ordinary rules below (invalid color and skipped if occupied by a non-belt building or invalid terrain; re-oriented if it already holds a belt). The rest of the L-shaped path is computed from the anchor to this end tile exactly as above. The end tile's belt direction points **toward the target** (across the shared input edge), overriding the "final tile keeps its incoming step" rule; this applies whether the end tile is a newly placed belt or an existing belt re-oriented in place, and is reflected both in the ghost preview and in the placement on release. - **Rotating during the drag.** Rotating the belt with R / Shift+R (REQ-BLD-ROTATE) while a drag is in progress re-picks the path's primary axis immediately from the new orientation and re-derives the whole path from the anchor to the current cursor tile, without waiting for the next cursor movement. @@ -154,7 +154,7 @@ Any ship, module, building, or assembler recipe id that appears in no unlock gro - REQ-BLD-SMELTER: **Smelter** (2×2): Converts ore or scrap into basic materials. No recipe selection required. Inputs, outputs, and rates are defined in `recipes.toml [[recipe]]` entries with `building = "smelter"`. - REQ-BLD-ASSEMBLER: **Assembler** (3×3): The player selects a recipe from the config-defined crafting tree. Produces the selected output item at the rate defined in the corresponding `recipes.toml [[recipe]]` entry with `building = "assembler"`. Only implicitly unlocked recipes are available for selection (REQ-LOCK-UI-RECIPE). - REQ-BLD-REPROCESSING: **Reprocessing Plant** (3×3): Consumes scrap per cycle and produces exactly one higher-level intermediate product per cycle via weighted random pick. The input quantity, possible output items, per-output weights, and amounts are defined in `recipes.toml [[recipe]]` entries with `building = "reprocessing_plant"` (`inputs`, `outputs[].item`, `outputs[].amount`, `outputs[].weight`). Weights are normalized at load time; their sum does not need to equal 1. The output is rolled at cycle start (see REQ-MAT-CYCLE); the pool of eligible outputs is restricted to implicitly unlocked item types (REQ-LOCK-REPROCESSING-POOL). The output buffer holds at most one cycle's output — see REQ-MAT-OUTPUT-BUFFER-REPROCESSING. -- REQ-BLD-SHIPYARD: **Shipyard** (4×2): The player selects a schematic. When all required materials — the ship's base materials (`[ship.schematic].materials`) plus the materials of all modules in the configured layout (REQ-MOD-MATERIALS) — are present in its input buffer, the shipyard consumes them and begins a production cycle lasting the ship's base `[ship.schematic].production_time_seconds` plus the sum of production times contributed by all module instances in the configured layout (REQ-MOD-PRODUCTION-TIME). One ship of that type is spawned with the configured modules when the cycle completes. The shipyard cannot start a new cycle while one is in progress. If the player confirms a layout change (REQ-MOD-UI-DIALOG) while a production cycle is in progress, the current cycle is cancelled and all consumed materials are discarded; the shipyard returns to idle with the new layout configuration. +- REQ-BLD-SHIPYARD: **Shipyard** (4×2): The player selects a schematic. When all required materials — the ship's base materials (`[ship.schematic].materials`) plus the materials of all modules in the configured layout (REQ-MOD-MATERIALS) — are present in its input buffer, the shipyard consumes them and begins a production cycle lasting the ship's base `[ship.schematic].production_time_seconds` plus the sum of production times contributed by all module instances in the configured layout (REQ-MOD-PRODUCTION-TIME). One ship of that type is spawned with the configured modules when the cycle completes. The shipyard cannot start a new cycle while one is in progress. If the player confirms a layout change (REQ-MOD-UI-DIALOG) while a production cycle is in progress, the current cycle is cancelled and all consumed materials are discarded; the shipyard returns to idle with the new layout configuration. Confirming a layout identical to the one already configured is not a change and cancels nothing (REQ-MAT-INPUT-BUFFER). - REQ-BLD-SALVAGE-BAY: **Salvage Bay** (3×2): A dedicated drop-off point for salvage ships. It has an output buffer whose holding capacity is defined by the `output_buffer_capacity` field of the `salvage_bay` entry in `buildings.toml` (rather than by a production cycle, since the Salvage Bay has no recipe). A ship at the bay hands over one unit of scrap per tick while the buffer has free space; a full buffer blocks further drop-off until space frees up (consistent with the buffer-full semantics of REQ-MAT-OUTPUT-BUFFER). Held scrap is pushed onto connected output belts. - REQ-BLD-BELT: **Belt** (1×1): Transports items. A belt tile has one direction (N, S, E, W) set at placement (modified by rotation). Curved belts are auto-derived: when a belt tile's outgoing direction leads into another belt whose direction is orthogonal, the downstream belt is rendered and behaves as a curve. Belt speed is defined in `world.toml [world].belt_speed_tiles_per_second` (REQ-GW-BELT-SPEED). A belt accepts items only through a non-output edge (REQ-MAT-ACCEPT-DIR). - REQ-BLD-SPLITTER: **Splitter** (1×1): Distributes incoming items between two output directions. Incoming items are accepted only through the splitter's non-output edges (REQ-MAT-ACCEPT-DIR). Each output can optionally have a filter (a list of item types), configurable via the selected building panel; only implicitly unlocked item types are available as filter options (REQ-LOCK-UI-SPLITTER). Routing rules: @@ -198,7 +198,8 @@ Any ship, module, building, or assembler recipe id that appears in no unlock gro - **Scope.** Direct coupling is the only case in which materials move between buildings without a belt, splitter, or tunnel (REQ-MAT-BELT-ONLY); it bridges only two buildings that are directly adjacent with meeting output/input ports. Transport tiles feeding a building (belt, splitter, or tunnel exit) continue to work through the normal pull, and a producer still hands off to a transport tile placed in the gap as before; a single such tile between two buildings is unaffected by this requirement. - REQ-MAT-ACCEPT-DIR: A transport tile (belt, splitter, tunnel entry, or tunnel exit) accepts an incoming item only through a non-output edge; an item that would enter through one of the tile's output edges is refused. For a belt or a tunnel entry/exit the sole output edge is the one in its facing direction; for a splitter either of its two output directions is an output edge. This applies both to items pushed from an adjacent transport tile and to items deposited by a building's output port (REQ-MAT-OUTPUT-PORT). - REQ-MAT-INPUT-BUFFER: Each building has one input buffer per required input material. Each per-material buffer holds up to twice that material's per-cycle requirement. When the player selects a new recipe or schematic, all items in all input buffers are cleared. -- REQ-MAT-OUTPUT-BUFFER: Each building has an output buffer that holds up to twice the quantity produced by one production cycle. If the output buffer is full, production stops until space is available. When the player selects a new recipe or schematic, all items in the output buffer are cleared (relevant when the adjacent belt is jammed and items have accumulated). + - **Setting a configuration to the value it already holds is a no-op.** Selecting the recipe or schematic already set, or applying a ship layout identical to the one already configured, changes nothing: buffers are not cleared, an in-progress production cycle is not cancelled (REQ-BLD-SHIPYARD), and a construction site's progress and stored settings are untouched. This holds however the setting is applied — through the selection dialog (REQ-UI-SELECT-BUTTON), the layout configuration dialog (REQ-MOD-UI-DIALOG), a blueprint placement (REQ-UI-BLUEPRINT-PLACE), or a blueprint configuration transfer (REQ-UI-BLUEPRINT-TRANSFER). Only a setting that genuinely differs has effects. +- REQ-MAT-OUTPUT-BUFFER: Each building has an output buffer that holds up to twice the quantity produced by one production cycle. If the output buffer is full, production stops until space is available. When the player selects a new recipe or schematic, all items in the output buffer are cleared (relevant when the adjacent belt is jammed and items have accumulated). Re-applying a setting the building already has clears nothing, per REQ-MAT-INPUT-BUFFER. - REQ-MAT-OUTPUT-BUFFER-REPROCESSING: Exception to REQ-MAT-OUTPUT-BUFFER — the Reprocessing Plant's output buffer holds at most one cycle's output. This prevents exploits where the player stalls the output belt to force the plant to reroll. - REQ-MAT-CYCLE: Production cycle lifecycle. When a building is idle, it attempts to start a new cycle: (a) all required inputs must be present in the per-material input buffers, and (b) the cycle's output must fit in the output buffer. For the Reprocessing Plant, the output is picked at cycle start (weighted pick); the cycle only starts if that chosen output fits. On cycle start, inputs are consumed immediately and the production timer begins. On cycle completion, the (already-decided) output is deposited into the output buffer and the building returns to idle. - REQ-MAT-GLOBAL-STOCK: The building blocks stock is the only global inventory. All other materials exist only in building buffers or on belt tiles. @@ -605,9 +606,36 @@ Blueprints occupy no permanent screen space. They are saved with **Ctrl+C** from Clicking anywhere on an enabled card other than its delete icon closes the dialog and enters blueprint placement mode for that blueprint (REQ-UI-BLUEPRINT-MODE). A card is disabled when the player cannot currently afford its total cost; a disabled card is rendered dimmed and clicking it does nothing (consistent with REQ-UI-BUILD-DISABLED), and neither closes the dialog nor enters placement mode. The delete icon is always enabled regardless of whether the player can afford the blueprint. -- REQ-UI-BLUEPRINT-MODE: In blueprint placement mode a ghost is rendered for every building in the blueprint (excluding any of a currently locked building type, REQ-LOCK-BUILDING, which is omitted entirely per REQ-LOCK-UI-BLUEPRINT) at the position determined by its stored tile offset from the bounding-box center, which is anchored to the tile under the cursor. Each ghost is rendered individually as valid or invalid, applying REQ-BLD-PLACE-VALID conditions (a) and (b) per building (the other ghosts in the same blueprint do not count as existing buildings for the overlap check). A valid ghost uses its building type's semi-transparent per-building coloring (REQ-BLD-GHOST); an invalid ghost uses the distinct "invalid" color, as in single-building builder mode. Pressing R / Shift+R rotates the entire constellation 90° counter-clockwise / clockwise: each building's tile offset is rotated around the bounding-box center and each building's own rotation is updated, consistent with REQ-BLD-ROTATE. Blueprint placement mode is exited by right-clicking in the game world. Opening the blueprint selection dialog while placement mode is active (REQ-UI-BLUEPRINT-DIALOG) leaves the mode active — closing the dialog without picking a card returns to it unchanged — while clicking a card exits the current mode and enters blueprint placement mode for the newly picked blueprint. +- REQ-UI-BLUEPRINT-MODE: In blueprint placement mode a ghost is rendered for every building in the blueprint (excluding any of a currently locked building type, REQ-LOCK-BUILDING, which is omitted entirely per REQ-LOCK-UI-BLUEPRINT) at the position determined by its stored tile offset from the bounding-box center, which is anchored to the tile under the cursor. Each ghost is rendered individually as valid or invalid, applying REQ-BLD-PLACE-VALID conditions (a) and (b) per building (the other ghosts in the same blueprint do not count as existing buildings for the overlap check). A valid ghost uses its building type's semi-transparent per-building coloring (REQ-BLD-GHOST); an invalid ghost uses the distinct "invalid" color, as in single-building builder mode; a ghost over a configuration-transfer target uses the distinct "transfer" color instead of either (REQ-UI-BLUEPRINT-TRANSFER), and a ghost over a compatible overlap counts as valid and keeps the ordinary per-building coloring (REQ-UI-BLUEPRINT-OVERLAP). Pressing R / Shift+R rotates the entire constellation 90° counter-clockwise / clockwise: each building's tile offset is rotated around the bounding-box center and each building's own rotation is updated, consistent with REQ-BLD-ROTATE. Blueprint placement mode is exited by right-clicking in the game world. Opening the blueprint selection dialog while placement mode is active (REQ-UI-BLUEPRINT-DIALOG) leaves the mode active — closing the dialog without picking a card returns to it unchanged — while clicking a card exits the current mode and enters blueprint placement mode for the newly picked blueprint. -- REQ-UI-BLUEPRINT-PLACE: Buildings of a currently locked building type (REQ-LOCK-BUILDING) are first excluded from the blueprint for this placement, per REQ-LOCK-UI-BLUEPRINT — they are not ghosted, not validity-checked, not placed, and their cost is excluded from the total. Left-clicking in blueprint placement mode then places the (remaining) blueprint if (a) every building in the constellation satisfies REQ-BLD-PLACE-VALID conditions (a) and (b) at its resolved tile, and (b) the player has enough building blocks to afford the total cost. If both conditions are met, a construction site is added to the build queue for each building in the blueprint and the full total cost is deducted from the global building blocks stock in one transaction. If a recipe ID is stored for a building, it is applied to the construction site immediately. If a schematic ID is stored, it is applied only if that schematic is currently unlocked; if it is not unlocked, the shipyard's schematic is left unset. If splitter output filters are stored, they are applied to the construction site immediately and carry over when it finishes building (REQ-BLD-SITE-CONFIG). Locked recipe IDs and splitter filter entries for locked item types are handled on placement per REQ-LOCK-UI-BLUEPRINT. After a successful placement the game remains in blueprint placement mode, allowing the player to place the same blueprint again immediately. +- REQ-UI-BLUEPRINT-PLACE: This describes placing the blueprint as new construction sites. A single-building blueprint whose ghost sits on a configuration-transfer target instead transfers its settings to the existing building and places nothing (REQ-UI-BLUEPRINT-TRANSFER); the rules below do not apply to that click. Buildings of a currently locked building type (REQ-LOCK-BUILDING) are first excluded from the blueprint for this placement, per REQ-LOCK-UI-BLUEPRINT — they are not ghosted, not validity-checked, not placed, and their cost is excluded from the total. Left-clicking in blueprint placement mode then places the (remaining) blueprint if (a) every building in the constellation satisfies REQ-BLD-PLACE-VALID conditions (a) and (b) at its resolved tile, and (b) the player has enough building blocks to afford the total cost. Buildings that are compatible overlaps (REQ-UI-BLUEPRINT-OVERLAP) are excluded from the total cost and are not placed, but do not block the placement. If both conditions are met, a construction site is added to the build queue for each remaining building in the blueprint and the full total cost is deducted from the global building blocks stock in one transaction. If a recipe ID is stored for a building, it is applied to the construction site immediately. If a schematic ID is stored, it is applied only if that schematic is currently unlocked; if it is not unlocked, the shipyard's schematic is left unset. If splitter output filters are stored, they are applied to the construction site immediately and carry over when it finishes building (REQ-BLD-SITE-CONFIG). Locked recipe IDs and splitter filter entries for locked item types are handled on placement per REQ-LOCK-UI-BLUEPRINT. After a successful placement the game remains in blueprint placement mode, allowing the player to place the same blueprint again immediately. + +- REQ-UI-BLUEPRINT-OVERLAP: **Compatible overlap.** In blueprint placement mode, a ghost whose footprint **exactly coincides** with the footprint of an existing placed building or construction site that is of the **same building type** and has the **same rotation** is a *compatible overlap*: the building the blueprint wants is already there. Such a ghost is **valid** despite the occupied tiles (REQ-BLD-PLACE-VALID condition (b)), so it does not block the placement of the rest of the constellation — dropping a blueprint over a partially-built copy of itself fills in what is missing. It is drawn in the ordinary per-building ghost color (REQ-BLD-GHOST), like any other valid ghost. + + On placement the overlapped building is **left completely untouched**: no construction site is placed on it, no building blocks are charged for it (it is excluded from the total cost of REQ-UI-BLUEPRINT-PLACE), its rotation is not changed, its configuration is not changed, and a construction site's progress is preserved. This applies per building in the blueprint, independently, and to blueprints of any size. Unlike REQ-BLD-ROTATE-IN-PLACE, which it replaces in this mode, it applies to Tunnel Entries and Tunnel Exits too — nothing is re-oriented, so the reason for their exception does not arise. + + A coinciding same-type building whose **rotation differs** is not a compatible overlap: the blueprint cannot rotate it (REQ-BLD-ROTATE-IN-PLACE no longer applies here), so the position is an ordinary occupied-tile overlap and therefore invalid. + + **Order of the two rules.** A ghost over a coinciding same-type building is tested for a configuration transfer (REQ-UI-BLUEPRINT-TRANSFER) first, and this requirement governs only what that test does not claim. Since a transfer requires a single-building blueprint of a configurable type, the split is: + - **Single-building blueprint, configurable type** (Miner, Assembler, Shipyard, Splitter) — always a transfer, at any target rotation. This requirement never applies. + - **Single-building blueprint, type with no settings** (Smelter, Reprocessing Plant, Salvage Bay, belt, tunnel end) — a compatible overlap if the rotation matches, invalid otherwise. Clicking places nothing and does nothing. + - **Multi-building blueprint** — every ghost is judged by this requirement alone, whatever its type: a coinciding same-type, same-rotation building is left untouched and the rest of the constellation is placed around it. No building in a multi-building blueprint ever transfers configuration. + +- REQ-UI-BLUEPRINT-TRANSFER: **Configuration transfer.** A single-building blueprint doubles as a way to copy one building's settings onto other buildings of the same type: select a configured building, press **C** to capture it as a temporary blueprint and enter placement mode (REQ-UI-BLUEPRINT-TEMP), then click same-type buildings to stamp its settings onto them. **V** re-enters that mode later. + + A blueprint ghost is a **configuration-transfer target** when all of the following hold: + - The blueprint holds **exactly one** building. A blueprint of two or more buildings never transfers, in whole or in part. + - That building is of a **configurable building type** — one with player-facing settings: Miner and Assembler (recipe), Shipyard (schematic and module layout), Splitter (output filters). Whether anything was actually configured at capture time is irrelevant; an unconfigured source transfers its unconfigured state (see below). Building types with no settings at all (Smelter, Reprocessing Plant, Salvage Bay, belts, tunnel entries and exits, the HQ) never transfer. + - The ghost's footprint **exactly coincides** with the footprint of an existing placed building or construction site of the same building type: the same coincidence test as REQ-BLD-ROTATE-IN-PLACE. A ghost that merely overlaps such a building without coinciding is not a transfer target. The target's **rotation is irrelevant** — a transfer never rotates anything, so a differently-facing target transfers exactly like an identically-facing one. + + At a transfer target: + - The ghost is drawn in a distinct **transfer** color read from `visuals.toml [overlays]`, overriding both the per-building coloring and the "invalid" color (REQ-BLD-GHOST, REQ-BLD-PLACE-VALID). The position counts as valid despite the occupied tiles (REQ-BLD-PLACE-VALID condition (b)). + - **Left-clicking transfers the configuration** to the existing building or site, making the target's settings **identical to the source's**: the recipe ID (Miner, Assembler), the schematic ID together with the ship layout (Shipyard), or the two output filters (Splitter). No construction site is placed, no building blocks are consumed, and the target's **rotation is not changed** — a transfer never rotates. + - The transfer is a **full mirror, including the absence of a setting**: where the blueprint stores no configuration for a field (REQ-UI-BLUEPRINT-STORAGE stores nothing for an unselected recipe or schematic, and no filter lists for a splitter whose filters were empty at capture time), the target's corresponding setting is **cleared** rather than left as it was. So a splitter captured with no filters clears the target splitter's filters back to accept-all, and a miner captured with no recipe selected clears the target miner's recipe. + - The transfer has the same effects as making that selection through the selected building panel, clearing included: buffer clearing per REQ-MAT-INPUT-BUFFER and REQ-MAT-OUTPUT-BUFFER, and, for a Shipyard, in-progress cycle cancellation per REQ-BLD-SHIPYARD. It inherits the no-op rule of REQ-MAT-INPUT-BUFFER with them: a transfer onto a building whose settings already match the source changes nothing at all — no buffers cleared, no production cycle cancelled, no construction progress lost — so repeatedly clicking already-matching buildings is harmless. Each field is judged on its own, so transferring an identical recipe with a differing layout affects only the layout. The layout configuration dialog does not auto-open (REQ-MOD-UI-AUTO-DIALOG). + - Unlock gating matches placement (REQ-UI-BLUEPRINT-PLACE): a stored schematic is applied only if it is currently unlocked, and locked recipe IDs and splitter filter entries for locked item types are handled per REQ-LOCK-UI-BLUEPRINT. + - Both operational buildings and construction sites are transfer targets (REQ-BLD-SITE-CONFIG); a configuration applied to a site carries over unchanged when it finishes building. + - After the transfer the game stays in blueprint placement mode, so further same-type buildings can be clicked in turn. - REQ-UI-BLUEPRINT-DELETE: Clicking the delete icon ("×") on a blueprint card (REQ-UI-BLUEPRINT-CARD) immediately removes that blueprint from the list, without a confirmation prompt. The blueprint selection dialog stays open and its card grid reflows to close the gap. If the deleted blueprint was active in blueprint placement mode, that mode is exited.